The Novo collection of pod vaping methods has historically been SMOK’s resolution for individuals who benefit from the comfort and small measurement of a pod-based system however need the expertise to be as handy as potential. The pods for nearly all SMOK Novo gadgets have built-in coils, which signifies that you benefit from the recent taste of a brand new coil each time you change the pod.
With the Novo 4, SMOK tried one thing a little bit totally different by giving the system a replaceable coil as a substitute of a built-in one. Utilizing a tool with a replaceable coil has some advantages. It provides you extra flexibility by way of vapor manufacturing and taste depth. Substitute coils additionally value lower than pods, so utilizing a vaping system with a replaceable coil helps to manage your recurring bills.
There are drawbacks, nonetheless, to utilizing a tool with a replaceable coil. Switching to the Novo 4 after utilizing a tool with a built-in coil will increase the quantity of upkeep you want to carry out. If you happen to do one thing incorrectly, your Novo 4 could show an error message you’ve by no means seen earlier than reminiscent of “Ohms Too Low” or “Ohms Too Excessive.”
The excellent news is that the fixes for these errors are often fairly easy. On this article, we’ll clarify what you want to do. Earlier than we get began, although, what’s truly occurring when your Novo 4 shows considered one of these errors?
What Is a Novo 4 “Ohms Too Low” or “Ohms Too Excessive” Error?
In vaping, {the electrical} resistance of the atomizer coil is likely one of the elements that determines the amperage drawn from the battery. It’s vital for the amperage to be throughout the battery’s secure limits, so a tool just like the SMOK Novo 4 scans the coil resistance to substantiate that it’s throughout the anticipated vary. The Novo 4 is suitable with a restricted set of coils, so it is aware of what the resistance of the put in coil must be. No Novo 4 coil ought to ever be outdoors the anticipated vary. Whether it is, the system will cease working and show the message “Ohms Too Low” or “Ohms Too Excessive.”
Verify that the Pod and Coil Are Right
The SMOK Novo 4 solely works with SMOK Novo 4 pods and SMOK LP1 coils. In case your Novo 4 shows an error message indicating that the coil’s resistance is just too low or too excessive, the very first thing that it is best to do is verify you’re utilizing the proper . If you happen to do handle to get a unique SMOK coil or Novo pod to slot in your system, it gained’t work.
You additionally have to be sure that the coil is put in accurately when utilizing the SMOK Novo 4. If you happen to have a look at the bottom of a SMOK LP1 coil, you’ll see that it has two flat edges to make sure appropriate set up. The flat edges on the base of the pod have to align with the flat edges on the backside of the Novo 4 pod. In the event that they don’t align, you gained’t be capable of push the coil in all the way in which. In that case, the Novo 4 could learn the coil’s resistance incorrectly. The pod may additionally leak, which is a matter we’ll talk about in additional element shortly.
Verify that the Wattage Is Right for the Put in Coil
The SMOK Novo 4 operates at a most energy of 25 watts, however that doesn’t imply it’ll essentially work effectively with all coils at that energy degree. If you happen to set the system’s energy degree too excessive, the system will most likely produce a burnt taste – however that’s not all. When a vape coil overheats, the ensuing stress to the steel can cause the coil’s resistance to change. In that case, the Novo 4 could say that the coil’s resistance is just too low or too excessive. If the coil has been broken resulting from overheating, there’s no strategy to repair this error; you’ll want to switch the coil.
There are 5 totally different coils within the SMOK LP1 collection, and every coil is suitable with the Novo 4. These are the facility ranges that SMOK suggests for every of the 5 coils.
- Meshed 0.8-ohm coil: 12 watts
- DC MTL 0.8-ohm coil: 12 watts
- Meshed 1.2-ohm coil: 10-15 watts
- Meshed 0.9-ohm MTL coil: 17 watts
- Turbo Meshed 0.9-ohm MTL coil: 17 watts
Change the Coil
Is your Novo 4 nonetheless displaying an error message concerning the coil’s resistance regardless that you’re sure that the system’s configuration is appropriate? On this case, it’s potential that the coil is broken or faulty. Attempt putting in a brand new coil. If the Novo 4 nonetheless doesn’t work, transfer the brand new coil to a brand new pod and take a look at vaping once more.
Verify for a Leak Below the Pod
If you happen to’re unable to resolve the Novo 4’s “Ohms Too Low” or “Ohms Too Excessive” error message with the recommendation given up to now on this information, it is best to take away the pod and look at the chamber on the prime of the Novo 4. If you happen to see e-liquid within the chamber, the pod has leaked. The moisture is stopping the Novo 4 from detecting the coil’s resistance accurately. Right here’s what it is best to do in case your Novo 4 leaks.
- Dry the within of the Novo 4 and the underside of the pod with a paper towel. Make it possible for the coil is aligned accurately and pushed all the way in which in. If the whole lot appears to be like good, attempt vaping once more.
- If the Novo 4 nonetheless isn’t working, take away the pod once more. Blow laborious by means of the airflow management ring whereas holding a paper towel over the chamber on the prime of the Novo 4. If the paper towel is moist, you’ve efficiently expelled a number of the vape juice from the within of the system. Dry the chamber on the prime of the Novo 4 and take a look at vaping once more.
- If the system nonetheless isn’t working, place the Novo 4 in a plastic bag with desiccant packets for a few days. Hopefully, the desiccant will absorb the last of the moisture from the Novo 4 and get the system working once more.